The mountain fire early warning and monitoring system for transmission lines ensures the safety of the power grid.
Contact Info
- Add:C-9/F, Building C, Jingda Industrial Park, No. 39 Qingfeng Avenue, Longgang Street, Longgang District, Shenzhen, Zip: 518116
- Contact: 李女士
- Tel:13682351635
- Email:1920671927@qq.com
Other Products
Product Aliases: Transmission Line Wildfire Early Warning and Monitoring System, Transmission Line Wildfire Prevention Online Monitoring Device, Power Grid Wildfire Online Monitoring Device, Transmission Line Fire Monitoring System, Transmission Line Wildfire Remote Monitoring Device, Transmission Line Wildfire Video Monitoring System
Product Model: TLKS-PMG-DF
1.Product Overview:
In the vast natural environment, transmission lines are like the blood vessels of the power grid, shouldering the important task of energy transmission. However, complex terrain and changeable climatic conditions make wildfires a potential risk affecting the safety of the power grid. To address this challenge, Telcom Technology, relying on its profound technical accumulation and spirit of continuous innovation, has launched the Transmission Line Wildfire Prevention Online Monitoring Device, building a solid green defense line for the safety of the power grid.
2.Working Mechanism:
The Transmission Line Wildfire Prevention Online Monitoring Device is a high-tech product specially designed for the wildfire protection needs of power networks. This device integrates multiple advanced technologies such as photoelectric composite temperature measurement technology, intelligent recognition algorithm, over-the-horizon visual monitoring system and wildfire platform management system, which can comprehensively perceive the environmental changes around transmission lines, accurately identify fire hazards, and issue early warnings in a timely manner, providing valuable time for rapid response and effective response to wildfires.
3. Product Function Highlights:
1. Real-time Monitoring: This system can monitor the mountain forest environment around transmission lines in real time, and timely detect abnormal situations such as mountain forest fires and illegal logging.
2. Automatic Recognition: The system adopts intelligent image analysis technology, which can automatically identify abnormal situations such as fire points and smoke, and accurately locate abnormal areas.
3. Remote Management: This system can remotely monitor the environment around transmission lines via mobile phones or computers, and grasp the operation status of transmission lines at any time, improving the management efficiency of operation and maintenance personnel.
4. Data Transmission: The system can send monitoring data to the background monitoring center regularly, ensuring the timeliness and integrity of data, and also supporting the breakpoint resume function.
4. Technical Parameters Introduction:
1. Image Mirroring: Horizontal, vertical, and 180° flip;
2. Power Supply Mode: Solar battery;
3. Communication Requirements: Supports wireless communication, and operators can be selected according to local conditions;
4. Working Voltage: DC12V
5. Temperature Measurement Range: -20℃~+150℃, 0℃~+550℃;
6. Temperature Measurement Accuracy: ±2℃/2%.
5. Product Summary:
The Transmission Line Wildfire Prevention Online Monitoring Device is an important innovation of Telcom Technology in the field of power safety monitoring. Through advanced real-time monitoring capabilities and intelligent data processing methods, it effectively reduces the power safety risks caused by wildfires and improves the stability of the entire power grid operation. We firmly believe that with the wide application of the TLKS-PMG-DF Device, the safety protection capability of the power grid will be greatly enhanced, promoting the power industry to make new breakthroughs in safety management and scientific and technological progress.
For device details, please consult Ms. Li from Telcom:
Phone: 13682351635; (WeChat is synchronized)
The customized product quotation is a market reference price, and the actual price needs to be negotiated by phone.
6. Usage Notes:
1. During the customization process, both parties shall protect intellectual property rights and avoid infringement risks.
2. Conduct technical evaluation on the user's customized requirements to ensure that they can be realized and meet the requirements.
3. Regularly perform appearance inspection, performance testing, and cleaning and maintenance on the device, and timely detect and solve problems.
4. Before installation, please carefully read the product installation manual to understand the installation steps, required tools, and safety requirements.
5. After installation, perform system debugging and testing to ensure normal functions and accurate data transmission.
| Industry Category | Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards |
|---|---|
| Product Category | |
| Brand: | 特力康 |
| Spec: | TLKS-PMG-DF |
| Manufacturer: | 深圳市特力康科技有限公司 |
| Origin: | 114403 |